Start signal selection (Terminal STF, STR, STOP, Pr. 250)
You can select the operation of the start signal (STF/STR).
Used to select the stopping method (deceleration to a stop or coasting) when the start signal turns off.
Used to stop the motor with a mechanical brake, etc. together with switching off of the start signal.
(Refer to section 6.9.3 for stop selection.)
The above parameter can be set when Pr. 160 "User group read selection" = 0.
2-wire type (terminals STF and STR)
A two-wire type connection is shown below.
In the initial setting, the forward/reverse rotation signals (STF/STR) are used as start and stop signals.
Turn on either of the forward and reverse rotation signals to start the motor in the corresponding di-
rection. If both are turned off (or on) during operation, the inverter decelerates to a stop.
The speed setting signal may either be given by entering 0 to 10 V DC across the speed setting input
terminal 2-5, by setting the required values in Pr. 4 to Pr. 6 "Multi-speed setting" (high, middle, low
speeds), etc. (For multi-speed operation, refer to section 6.6.1).
When Pr. 250 is set to any of "1000 to 1100, 8888", the STF signal becomes a start command and the
STR signal a forward/reverse command.
Pr. No. Name
Initial Value
Setting
Range
Description
Parameters referred to
Refer to
Section
Start Signal (STF/STR)
Stop Operation
250
Stop selection
9999
0–100 s
STF: Forward
rotation start
STR: Reverse rotation
start
The motor is coasted to a stop
when the preset time elapses
after the start signal is turned
off.
4–6
178–184
Multi-speed setting
Input terminal function
selection
1000 s
–
1100 s
STF: Start signal
STR: Forward/reverse
signal
The motor is coasted to a stop
(Pr. 250 1000)s after the start
signal is turned off.
9999
STF: Forward
rotation start
STR: Reverse
rotation start
When the start signal is turned
off, the motor decelerates to
stop.
8888
STF: Start signal
STR: Forward/reverse
signal
Fig. 6-55:
2-wire type connection (Pr. 250 = 9999)
I001148E
Forward rotation start
Reverse rotation start
Inverter
Output fr
equenc
y
For
w
ar
d
rota
tion
Rev
erse
rotation
Time
ON
ON
Содержание fr-e700 series
Страница 2: ......
Страница 4: ......
Страница 20: ...Contents XVI ...
Страница 112: ...Operation panel Operation 4 20 ...
Страница 154: ...External operation Basic settings 5 42 ...
Страница 528: ...CC Link IE Field Network Basic Parameter 6 374 ...
Страница 562: ...Meters and measuring methods Troubleshooting 7 34 ...
Страница 606: ...A 30 Index Appendix ...
Страница 607: ......