Selection of operation mode and operation location
Parameter
6 - 218
6.18.2
Operation mode at power on (Pr. 79, Pr. 340)
When power is switched on or when power comes back on after instantaneous power failure, the
inverter can be started up in network operation mode.
After the inverter has started up in the network operation mode, parameter write and operation can
be performed from a program.
Set this mode for communication operation using the inverter RS-485 terminals or communication
option.
The above parameters can be changed during a stop in any operation mode.
햲
The above parameter can be set when Pr. 160 "User group read selection" = 0. However, the
parameters can be set whenever the communication option is connected. (Refer to section
6.17.4.)
Pr. No. Name
Initial Value
Setting
Range
Description
Parameters referred to
Refer to
Section
79
Operation mode selection
0
0–4/6/7
Select the operation mode.
(Refer to page 6-209)
79 Operation mode selection 6.18.1
340
Communication start-up
mode selection
햲
0
0
As set in Pr. 79.
1
Started in network operation mode.
10
Started in network operation mode. Operation mode
can be changed between the PU operation mode and
network operation mode from the operation panel.
Содержание fr-e700 series
Страница 2: ......
Страница 4: ......
Страница 20: ...Contents XVI ...
Страница 112: ...Operation panel Operation 4 20 ...
Страница 154: ...External operation Basic settings 5 42 ...
Страница 528: ...CC Link IE Field Network Basic Parameter 6 374 ...
Страница 562: ...Meters and measuring methods Troubleshooting 7 34 ...
Страница 606: ...A 30 Index Appendix ...
Страница 607: ......