Parameter
CC-Link IE Field Network Basic
FR-E700 SC EC/ENE
6 - 363
Monitor codes
Information about the inverter can be monitored by setting the special monitor selection No. of the
instruction code and monitor code using the remote registers, RWw0 and RWw4 to 7.
●
For the monitor code (RWw0), select the first monitor description (RWr0) from the lower 8 bits and
the second monitor description (RWr1) from the upper 8 bits.
Example:
When output current is selected for the first monitor (RWr0) and output voltage is selected for the
second monitor (RWr1), the monitor code (RWw0) is H0302.
●
When Pr. 544 = "12, 14, or 18", descriptions of monitor codes 3 (RWw4) to 6 (RWw7) can be selected.
햲
When Pr. 37 is not equal to "0", this will be machine speed display (1 increments).
Monitor code
Second monitor
description (the first 8 bits)
First, third to sixth monitor
description (the last 8 bits)
Increments
H00
Output frequency/machine
speed
No monitoring
(monitor value is 0)
0.01 Hz/1
H01
Output frequency/machine speed
0.01 Hz/1
H02
Output current
0.01 A
H03
Output voltage
0.1 V
H05
Frequency setting value/machine speed setting
0.01 Hz/1
…
…
…
Tab. 6-162:
Monitor codes for selecting different information about the inverter
NOTE
The monitor codes from H01 and up and their contents are the same as those of the RS-485 com-
munication dedicated monitor. For the details of the monitor codes or monitor items, refer to page
6-140.
Содержание fr-e700 series
Страница 2: ......
Страница 4: ......
Страница 20: ...Contents XVI ...
Страница 112: ...Operation panel Operation 4 20 ...
Страница 154: ...External operation Basic settings 5 42 ...
Страница 528: ...CC Link IE Field Network Basic Parameter 6 374 ...
Страница 562: ...Meters and measuring methods Troubleshooting 7 34 ...
Страница 606: ...A 30 Index Appendix ...
Страница 607: ......