Parameter overview
Parameter
6 - 30
햲
This setting is only available for the FR-E700 SC ENE.
햳
The setting is applied after an inverter reset or power-ON.
햴
These parameters are communication parameters that are not cleared when parameter clear (All
parameter clear) is executed from Ethernet network (MODBUS®/TCP or CC-Link IE Field Network
Basic).
(Refer to page 6-333 for the details of the MODBUS®/TCP, and page 6-349 for the details of the CC-
Link IE Field Network Basic.)
Func-
tion
Parameter
Name
Incre-
ments
Initial
Value
Setting
Range
Description
Para-
meter-
Copy
Para-
meter
Clear
All
Para-
meter
Clear
Refer
to
Page
Rela
te
d
Paramet
ers
✔
: Enabled
—: Disabled
Ethernet C
ommunica
tion
850
햲
Ethernet TCP disconnection
time coefficient
1
3600
1–7200
When the inverter does not receive a packet
within the time calculated by multiplying
the Pr. 850 setting by 8 in seconds from the
devices with the TCP connection established,
the connection will be forcibly closed.
✔
✔
햴
✔
햴
851
햲
Ethernet signal loss detection
function selection
1
3
0, 2, 3
Set the availability of the signal loss
detection and select the action when
Ethernet communication is interrupted by
physical factors.
✔
✔
햴
✔
햴
852
햲
Ethernet communication
check time interval
0.1 s
1.5 s
0, 0.1–999.8 s,
9999
Set the interval of the communication check
(signal loss detection) time for all devices
with IP addresses in the range specified for
Ethernet command source selection (Pr. 844
to Pr. 849). If a no-communication state
persists for the permissible time or longer,
the inverter output is shut off.
✔
✔
햴
✔
햴
442
햲
,
햳
Default gateway address 1
1
0
0–255
Enter the IP address of the default gateway,
which is a device connecting the different
networks, to establish a communication
between the inverter and the devices
outside the inverter network.
✔
✔
햴
✔
햴
443
햲
,
햳
Default gateway address 2
1
0
0–255
✔
✔
햴
✔
햴
444
햲
,
햳
Default gateway address 3
1
0
0–255
✔
✔
햴
✔
햴
445
햲
,
햳
Default gateway address 4
1
0
0–255
✔
✔
햴
✔
햴
—
859
Refer to Pr. 84
872
Refer to Pr. 251
Regener
ation a
voidanc
e func
tion
882
Regeneration
avoidance operation selection
1
0
0
Regeneration avoidance function invalid
✔
✔
✔
1
Regeneration avoidance function is always
valid
2
Regeneration avoidance function is valid
only during a constant speed operation
883
Regeneration
avoidance operation level
0.1 V
400 V/
780 V *
300–800 V
Set the bus voltage level at which
regeneration avoidance operates. When the
bus voltage level is set to low, overvoltage
error will be less apt to occur. However, the
actual deceleration time increases.
The set value must be higher
than the "power supply
voltage x
冑
2.
* The initial value differs according to the
voltage class: 200 V/400 V
✔
✔
✔
885
Regeneration avoidance
compensation frequency limit
value
0.01 Hz
6 Hz
0–10 Hz
Set the limit value of frequency which rises
at activation of regeneration avoidance
function.
✔
✔
✔
9999
Frequency limit invalid
Tab. 6-1:
Parameter overview (30)
Содержание fr-e700 series
Страница 2: ......
Страница 4: ......
Страница 20: ...Contents XVI ...
Страница 112: ...Operation panel Operation 4 20 ...
Страница 154: ...External operation Basic settings 5 42 ...
Страница 528: ...CC Link IE Field Network Basic Parameter 6 374 ...
Страница 562: ...Meters and measuring methods Troubleshooting 7 34 ...
Страница 606: ...A 30 Index Appendix ...
Страница 607: ......