Parameter
CC-Link IE Field Network Basic
FR-E700 SC EC/ENE
6 - 359
●
Remote register (inverter to master module)
– Remote register definition
Device No.
Signal
Description
RWr0
First monitor value
When "1" is set in RYC, the specified monitored data is set to the lower 8 bits of the
monitor code (RWw0). When Pr. 37 "Speed display"
0 and output frequency or set
frequency monitor is set for monitor code (RWw0), machine speed setting (1 unit) is
monitored.
RWr1
Second monitor value
(Output frequency)
When "0" is set to the upper 8 bits of the monitor code (RWw0), the current output fre-
quency is always set. When a value other than "0" is set to the upper 8 bits of the mon-
itor code (RWw0) while "1" is set in RYC, the monitor data specified by the upper 8 bits
of the monitor code (RWw0) is set. When Pr. 37 "Speed display"
0 and output fre-
quency or set frequency monitor is set for monitor code (RWw0), machine speed set-
ting (1 unit) is monitored.
RWr2
Reply code (when Pr. 544 = 0)
When "1" is set in RYD or RYE, the reply code for the frequency setting command is
set. When "1" is set in RYF, the reply code corresponding to the instruction code RWw2
is set. The value "0" is set for a normal reply and any digit other than "0" is set for data
fault, mode error, etc. (Refer to page 6-360.)
Reply code 1 (when Pr. 544 0)
Lower 8 bits of RWr2
When "1" is set in RYD or RYE, the reply code for the frequency setting command is
set. (Refer to page 6-360.)
Reply code 2 (when Pr. 544
0)
Upper 8 bits of RWr2
When "1" is set in RYF, the reply code corresponding to the instruction code RWw2 is
set. (Refer to page 6-360.)
RWr3
Read data
For a normal reply, the reply data to the instruction specified by the instruction code
is set.
RWr4
Third monitor value
When "1" is set in RYC, the monitored data specified by the monitor code (RWw
쏔
) is
saved.
(
쏔
indicates a register number (RWw4 to 7)
When Pr. 37 "Speed display"
0 and output frequency or set frequency monitor is set
for monitor code (RWw0), machine speed setting (1 unit) is monitored.
RWr5
Fourth monitor value
RWr6
Fifth monitor value
RWr7
Sixth monitor value
RWr8
Fault record (fault data)
The fault data of faults history No. specified by RWw8 is stored in the lower 8 bits.
Upper 8 bits of RWw8 will be reverted back to the upper 8 bits.
RWr9
Fault record (output frequency)
Output frequency of the faults history No. specified in RWw8 is stored.
RWrA
Fault record (output current)
Output current of the faults history No. specified in RWw8 is stored.
RWrB
Fault record (output voltage)
Output voltage of the faults history No. specified in RWw8 is stored.
RWrC
Fault record (energization time)
Energization time of the faults history No. specified in RWw8 is stored.
RWr10 to
RWr19
Reply code
When "1" is set in RYF, the reply codes corresponding to the instruction code RWw10,
12, 14, 16, and 18 are set. The value "0" is set for a normal reply and other than "0" is
set for data fault, mode error, etc. (Refer to page 6-360.)
Read data
For a normal reply, the reply data to the instruction specified by the instruction code
is set.
Tab. 6-159:
Remote register definition (inverter
씮
master module)
Содержание fr-e700 series
Страница 2: ......
Страница 4: ......
Страница 20: ...Contents XVI ...
Страница 112: ...Operation panel Operation 4 20 ...
Страница 154: ...External operation Basic settings 5 42 ...
Страница 528: ...CC Link IE Field Network Basic Parameter 6 374 ...
Страница 562: ...Meters and measuring methods Troubleshooting 7 34 ...
Страница 606: ...A 30 Index Appendix ...
Страница 607: ......