Parameter
Parameter overview
FR-E700 SC EC/ENE
6 - 27
햲
These parameters are communication parameters that are not cleared when parameter clear (all
clear) is executed from RS-485 communication.
(Refer to section 6.19 for RS-485 communication.)
Func-
tion
Parameter
Name
Incre-
ments
Initial
Value
Setting
Range
Description
Para-
meter-
Copy
Para-
meter
Clear
All
Para-
meter
Clear
Refer
to
Page
Rela
te
d
Paramet
ers
✔
: Enabled
—: Disabled
Communica
tion
339
Communication speed
command source
1
0
0
Speed command source communication
✔
✔
햲
✔
햲
1
Speed command source external (Frequency
setting from communication is invalid,
terminal 2 setting from external is valid)
2
Speed command source external (Frequency
setting from communication is valid,
terminal 2 setting from external is invalid)
550
NET mode operation
command source selection
1
9999
0
Communication option valid
✔
✔
햲
✔
햲
2
PU connector valid
9999
Automatic recognition of the
communication option
Normally, PU connector is
valid.Communication option is valid when
the communication option is mounted.
551
PU mode operation command
source selection
1
9999
2
Selects the PU connector as the PU operation
mode control source
✔
✔
햲
✔
햲
3
Selects the USB connector as the PU
operation mode control source.
4
Selects the operation panel as the PU
operation mode control source.
9999
USB connection FR- PU07 connection
automatic recognition
Priorities: USB > FR-PU07 > operation panel
—
340
Refer to Pr. 79
342
343
Refer to Pr. 117 to Pr. 124
349
Refer to Pr. 124
442
–
445
Refer to Pr. 852
450
Refer to Pr. 71
Remot
e output func
tion (REM signal)
495
Remote output selection
1
0
0
Remote output
data clear at
powering off
Remote output data
clear at inverter reset
✔
✔
✔
1
Remote output
data retention at
powering off
10
Remote output
data clear at
powering off
Remote output data
retention at inverter
reset
11
Remote output
data retention at
powering off
496
Remote output data 1
1
0
0–4095
Output terminal can be switched on and off.
—
—
—
497
Remote output data 2
1
0
0–4095
—
—
—
—
501
502
Refer to Pr. 124
Tab. 6-1:
Parameter overview (27)
Содержание fr-e700 series
Страница 2: ......
Страница 4: ......
Страница 20: ...Contents XVI ...
Страница 112: ...Operation panel Operation 4 20 ...
Страница 154: ...External operation Basic settings 5 42 ...
Страница 528: ...CC Link IE Field Network Basic Parameter 6 374 ...
Страница 562: ...Meters and measuring methods Troubleshooting 7 34 ...
Страница 606: ...A 30 Index Appendix ...
Страница 607: ......