C00806
C00807
C00808
C00809
Parameter | Name:
C00806 | L_MPot_1: Use
Data type: UNSIGNED_8
Index: 23769
d
= 5CD9
h
The
FB: Use of the motor potentiometer
Selection list
(Lenze setting printed in bold)
Info
0 No
The motor potentiometer is not used.
• The analog value applied to the
nIn_a
input is looped
through without any changes to the
nOut_a
output.
1 Yes
The motor potentiometer is used.
• The analog value applied at the
nIn_a
input is led via
the motor potentiometer and provided at the
nOut_a
output.
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C00807 | L_NLim_1: Max.SkipFrq.
Data type: INTEGER_16
Index: 23768
d
= 5CD8
h
FB
: Maximum blocking frequencies
Setting range
(min. value | unit | max. value)
0.00
%
199.99
Subcodes
Lenze setting
Info
C00807/1
0.00 %
Maximum blocking frequency for zone 1
C00807/2
0.00 %
Maximum blocking frequency for zone 2
C00807/3
0.00 %
Maximum blocking frequency for zone 3
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 100
Parameter | Name:
C00808 | L_NLim_1: Min.SkipFrq.
Data type: INTEGER_16
Index: 23767
d
= 5CD7
h
FB
: Minimum skip frequencies
Setting range
(min. value | unit | max. value)
0.00
%
199.99
Subcodes
Lenze setting
Info
C00808/1
0.00 %
Minimum blocking frequency for zone 1
C00808/2
0.00 %
Minimum blocking frequency for zone 2
C00808/3
0.00 %
Minimum blocking frequency for zone 2
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 100
Parameter | Name:
C00809 | L_NLim_2: Max.SkipFrq.
Data type: INTEGER_16
Index: 23766
d
= 5CD6
h
FB
: Maximum skip frequencies
Setting range
(min. value | unit | max. value)
0.00
%
199.99