Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
1057
15
Parameter reference
15.2
Parameter list
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01092
C01093
Parameter | Name:
C01092 | LS_ParReadWrite 1-6: FailState
Data type: UNSIGNED_16
Index: 23483
d
= 5BBB
h
From version 04.00.00
Error status:
• 0 = no error
• 33803 | 0x840B = invalid data type (e.g. STRING)
• 33804 | 0x840C = limit violation
• 33806 | 0x840E = invalid code
• 33813 | 0x8415 = no element of the selection list
• 33815 | 0x8417 = writing of the parameter not permitted
• 33816 | 0x8418 = writing of the parameter only permitted if controller is inhibited
• 33829 | 0x8425 = invalid subcode
• 33865 | 0x8449 = no parameter with subcodes
Display range
(min. value | unit | max. value)
0
34000
Subcodes
Info
C01092/1
: Error status
C01092/2
: Error status
C01092/3
: Error status
C01092/4
: Error status
C01092/5
: Error status
C01092/6
: Error status
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C01093 - LS_ParReadWrite 1-6: Arithmetic mode
Data type: UNSIGNED_8
Index: 23482
d
= 5BBA
h
From version 06.00.00
allows for easy arithmetic conversion of the process value to be written or which
was read into the format of the target parameter via parameterisable factors and without the need for an
additional arithmetic FB.
Selection list
0 No arithmetic
1 In16Bit: LW=+/-32767
2 In16Bit: HW=+/-; LW=0..65535
3 In32Bit: HW_LW=+/-2147483647
Subcodes
Lenze setting
Info
C01093/1
0: no arithmetic
C01093/2
0: no arithmetic
C01093/3
0: no arithmetic
C01093/4
0: no arithmetic
C01093/5
0: no arithmetic
C01093/6
0: no arithmetic
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1