15
Parameter reference
15.2
Parameter list
954
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00700/6
0: Not connected
: nPIDActValue_a
Input for actual PID controller value
C00700/7
16000: LS_AnalogInput: nIn1_a
: nMainSetValue_a
Input for main speed setpoint
C00700/8
0: Not connected
: nAuxSetValue_a
Input for additional speed setpoint
C00700/9
0: Not connected
: nGPAnalogSwitchIn1_a
Input for analog switch - analog signal 1
C00700/10
0: Not connected
: nGPAnalogSwitchIn2_a
Input for analog switch - analog signal 2
C00700/11
0: Not connected
: nGPArithmetikIn1_a
Input for arithmetic function - analog signal 1
C00700/12
0: Not connected
: nGPArithmetikIn2_a
Input for arithmetic function - analog signal 2
C00700/13
0: Not connected
: nGPMulDivIn_a
Input for analog signal for multiplication/division
C00700/14
0: Not connected
: nGPCompareIn1_a
Input for comparison operation - analog signal 1
C00700/15
0: Not connected
: nGPCompareIn2_a
Input for comparison operation - analog signal 2
C00700/16
0: Not connected
: nVoltageAdd_a
Input for additive voltage boost
C00700/17
0: Not connected
: nPIDInfluence_a
Input for influence signal of PID controller correcting
variable
C00700/18
0: Not connected
: nPIDSetValue_a
Input for PID controller setpoint
C00700/19
0: Not connected
: nPWMAngleOffset
Input for pulse width modulation phase offset
C00700/20
0: Not connected
: nBoost_a
Input for additional setpoint for motor voltage at speed
= 0
C00700/21
0: Not connected
: wSMCtrl
Interface to the optional safety system
C00700/22
0: Not connected
Reserved
C00700/23
0: Not connected
Reserved
C00700/24
0: Not connected
Reserved
C00700/25
0: Not connected
Reserved
C00700/26
0: Not connected
: wFreeIn1
Input for user signal 1
C00700/27
0: Not connected
: wFreeIn2
Input for user signal 2
C00700/28
0: Not connected
: wFreeIn3
Input for user signal 3
C00700/29
0: Not connected
: wFreeIn4
Input for user signal 4
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C00700 | LA_NCtrl: Analog connection list
Data type: UNSIGNED_16
Index: 23875
d
= 5D43
h