Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
127
4
Device control (DCTRL)
4.4
Internal interfaces | "LS_DriveInterface" system block
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Inputs
Designator
DIS code | data type
Information/possible settings
wCANControl
| WORD
Control word via system bus (CAN)
• The inverter controlled by a master control (e.g. IPC) receives its control word by
the CANopen system bus interface. The process data word is provided at this
input by the upstream port block
.
• For a detailed description of the individual control bits, see chapter
wCANControl/wMCIControl control words
wMCIControl
| WORD
Control word via communication module (e.g. PROFIBUS)
• The inverter controlled by a master control (e.g. IPC) receives its control word by
a plugged-in communication module. The process data word is provided at this
input by the upstream port block
LP_MciIn1
.
• For a detailed description of the individual control bits, see chapter
wCANControl/wMCIControl control words
bCInh
| BOOL
FALSE Enable inverter: The inverter switches to the "
"
device status if no other source for controller inhibit is active.
•
provides a bit coded representation of all active
sources/triggers of a controller inhibit.
TRUE Inhibit inverter (controller inhibit): The inverter switches to the
" device status.
bFailReset
| BOOL
FALSE
TRUE The current error is reset.
bStatus_Bit0
bStatus_Bit2
bStatus_Bit3
bStatus_Bit4
bStatus_Bit5
bStatus_Bit14
bStatus_Bit15
| BOOL
Freely assignable bits in the status word of the inverter
• You can use these bits for returning information to the master control (e.g. IPC).
bFree_1
bFree_2
bFree_3
bFree_4
| BOOL
Reserved inputs have no function