Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
1446
17
Function library
17.1
Function blocks | L_Odometer_1
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Outputs
Parameters
Designator
Data type
Value/meaning
dnPosOut_1_p
...
dnPosOut_8_p
DINT
Detected positions
dnDeltaPos_12_p
dnDeltaPos_23_p
dnDeltaPos_34_p
...
dnDeltaPos_18_p
DINT
Calculated distances between the detected positions
•
dnDeltaPos_12_p
= Distance between
dnPosOut_1_p
and
dnPosOut_1_p
•
dnDeltaPos_23_p
= Distance between
dnPosOut_2_p
and
dnPosOut_3_p
•
dnDeltaPos_34_p
= Distance between
dnPosOut_3_p
and
dnPosOut_4_p
...
•
dnDeltaPos_18_p
= Distance between
dnPosOut_1_p
and
dnPosOut_8_p
wLastMeasure
WORD
Memory location number (1 ... 8) of the last measurement
Parameters
Possible settings
Info
Memory length
• Lenze setting: 7 measurements
1 1 measurement
2 2 measurements
... ...
7 7 measurements
Memory type
• Lenze setting: No ring buffer
0 No ring buffer
1 Ring buffer
Input selection
• Lenze setting: Pos input
0 Pos input
1 V input
Edge selection
• Lenze setting: HIGH edge
0 High edge
1 Low edge
2 High and low edge