Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
285
5
Motor control (MCTRL)
5.12
Position control/additive speed specification
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5.12
Position control/additive speed specification
In the Lenze setting, the position control is only active with
Proceed as follows to open the dialog for parameterising the position control:
1. »Engineer« Go to the
Project view
and select the 8400 HighLine inverter.
2. Select the
Application parameters
tab from the
Workspace
.
3. Go to the
Overview
dialog level and click the
Motor control...
button to change to the
Overview
motor control...
dialog level.
4. Click the
Position control
button in the displayed signal flow.
Parameters
Info
1
MCTRL: nSpeedSetValue_a
Speed setpoint
2
MCTRL: dnDeltaPos_p
Position difference (following error input)
3
MCTRL: dnPosSetValue_p
Absolute position setpoint
4
MCTRL: bDeltaPosOn
TRUE = Position difference is active as setpoint selection
5
Kp position controller
Gain for following error compensation
6
MCTRL: nPosCtrlPAdapt_a
Adaptation of the position controller gain
7
MCTRL: bPosDerivativeOn
TRUE = Setpoint for the speed controller is created from the position setpoint
8
MCTRL: nPosCtrlOutLimit_a
Limitation of the position controller output
9
MCTRL: bPosCtrlOn
TRUE = Position/angle control active