15
Parameter reference
15.2
Parameter list
1036
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00997
C00998
C00999
C01000
Parameter | Name:
C00997 | SLPSM: Filter cutoff frequency
Data type: INTEGER_16
Index: 23578
d
= 5C1A
h
From version 10.00.00
Sensorless control for synchronous motors (SLPSM)
Setting range
(min. value | unit | max. value)
Lenze setting
0.00
%
100.00
5.00 %
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 100
Parameter | Name:
C00998 | SLPSM: Filter time rotor position
Data type: INTEGER_16
Index: 23577
d
= 5C19
h
From version 10.00.00
Sensorless control for synchronous motors (SLPSM)
Setting range
(min. value | unit | max. value)
0.5
ms
20.0
Subcodes
Lenze setting
Info
C00998/1
3.0 ms
: Filter time rotor position
C00998/2
5.0 ms
: Filter time actual speed value
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 10
Parameter | Name:
C00999 | SLPSM: PLL gain
Data type: INTEGER_16
Index: 23576
d
= 5C18
h
From version 10.00.00
Sensorless control for synchronous motors (SLPSM)
Setting range
(min. value | unit | max. value)
Lenze setting
0
%
1000
400 %
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C01000 | MCTRL: Status
Data type: UNSIGNED_16
Index: 23575
d
= 5C17
h
From version 10.00.00
Display area
(min. hex value | max. hex value)
0x0000
0xFFFF
Value is bit-coded:
Info
Bit 0 SLPSM: Speed closed-loop control
1
≡
The sensorless control for synchronous motors is in
the closed-loop controlled operation (|n
Setpoint
| >
n
C00996
).
Sensorless control for synchronous motors (SLPSM)
Bit 1 SLPSM: Speed open-loop control
From version 12.00.00
1
≡
The sensorless control for synchronous motors is in
the open-loop controlled operation (|n
Setpoint
| > n
C00996
).
Sensorless control for synchronous motors (SLPSM)
Bit 2 Motor ASM
From version 12.00.00
1
≡
Set motor type is "Asynchronous motor"
Bit 3 Motor PSM
From version 12.00.00
1
≡
Set motor type is "Synchronous motor"