5
Motor control (MCTRL)
5.4
V/f characteristic control (VFCplus)
172
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Tip!
Cases of application for this function:
• Operation of reluctance motors or synchronous motors during controlled acceleration
(reduction of natural frequencies caused by wrong excitation).
• Adaptation of the voltage requirement for the motor, depending on specific load
conditions.
Proceed as follows to open the dialog for parameterising the motor control:
1. »Engineer« Go to the
Project view
and select the 8400 HighLine inverter.
2. Select the
Application parameters
tab from the
Workspace
.
3. Select the motor control "10: VFCplus: V/f definable" from the
Overview
dialog box in the
Motor control
list field:
4. Click the
Motor control V/f definable
button to change to the
Overview
Motor control V/f
dialog box.
• This dialog level only shows a simplified signal flow with the most important
parameters.
• When you click the
>>More details
button in the left-most position, a signal flow with
more details/parameters is displayed.