Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
367
6
I/O terminals
6.6
User-defined terminal assignment
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
6.6.2
Changing the terminal assignment with the keypad
You can reconfigure the preconfigured terminal assignment with the keypad (and with the
»Engineer«) by means of so-called configuration parameters.
• Each configuration parameter represents a signal input of a system block or application block.
• Each configuration parameter contains a selection list with output signals of the same type of
data.
• Logical linking is thus carried out by selecting the output signal for the corresponding signal
input.
In the following example, digital output 1 (
LS_DigitalOutput
.bOut1
input) is logically linked to the
status signal "Drive ready" (
LA_nCtrl_bDriveReady
output signal):
Configuration parameters for the analog and digital output terminals
The preconfigured assignment of the analog and digital output terminals can be altered by means
and
:
Other subcodes (not shown here) allow the configuration of input signals of different system blocks
and port blocks.
Parameters
Info
Lenze setting
Value Unit
Analog outputs - terminal assignment
LS_AnalogOutput: nOut1_a (V)
1003: LA_nCtrl_nMotorSpeedAct_a
LS_AnalogOutput: nOut1_a (I)
0: Not connected
LS_AnalogOutput: nOut2_a (V)
0: Not connected
LS_AnalogOutput: nOut2_a (I)
0: Not connected
Digital outputs - terminal assignment
LS_DigitalOutput:bRelay
1001: LA_nCtrl_bDriveFail
LS_DigitalOutput:bOut1
1000: LA_nCtrl_bDriveReady
LS_DigitalOutput: bOut2
0: Not connected
LS_DigitalOutput: bOut3
0: Not connected
LS_DigitalOutput: bOut HighCurrent
0: Not connected