Function library
17.1
Function blocks | L_Counter_1
1327
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
General function
• Every FALSE/TRUE edge at the
bClkUp
input causes the block to count upwards by "1".
• Every FALSE/TRUE edge at the
bClkDown
input causes the block to count downwards by "1".
Function "Normal counting"
If the statement of the comparison mode selected in
is true, the
bCompare
output is set
to TRUE.
Function "Auto reset"
If the statement of the comparison mode selected in
is true, the
bCompare
output is set
to TRUE for 1 ms and the counter is reset to the
wLdVal
starting value.
Function "Manual reset"
If the statement of the comparison mode selected in
is true, the
bCompare
output is set
to TRUE and the counter stops.
• Edges at
bClkUp
and
bClkDown
are ignored.
• The counter must be reset via the
bLoad
input.
Selection of comparison operation
• Lenze setting: Counter
content
≥
comparison value
0 Counter content
≥
comparison value
1 Counter content
≤
comparison value
2 Counter content = comparison value
Parameters
Possible settings
Info