TA "Table positioning"
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
nAccOverride_a
INT
Value for
• Percentage multiplier for the currently active acceleration.
• 16384
≡
100 % of the parameterised acceleration of the corresponding operating
mode.
• If the override value is 0 %, acceleration ceases.
bHomeStartStop
BOOL
: Start/stop homing
TRUE Start homing
TRUE
FALSE Stop homing
bHomeSetPosition
BOOL
: Set home position
TRUE Set home position
bHomeResetPosition
BOOL
: Reset home position
TRUE Reset the "Reference known" status
bHomeMark
BOOL
: Input for reference switch (pre-switch off mark)
• This input responds to the FALSE status (fail-safe) and is to be connected to the
corresponding digital input to which the reference switch is connected.
bPosSetProfilePosition
BOOL
: MCK setpoint position
TRUE Teach MCK setpoint position into the selected profile.
bPosSetActualPosition
BOOL
: Current position
TRUE Teach current position into the selected profile.
bPosExecute
BOOL
: Start travelling
FALSE
TRUE Execute selected profile
bPosFinishTarget
BOOL
: Complete cancelled profile
FALSE
TRUE A positioning process previously cancelled, e.g. by
bPosStop
or due to
a device error, is resumed by travelling to the original target.
bPosDisableFollowProfile
BOOL
: Do not execute sequence profile (switch-off profile linkage)
TRUE Evaluation of the sequence profile number parameterised in
for the selected profile is suppressed.
bPosStop
BOOL
: Cancel travelling
TRUE Stop positioning
From version 11.00.00
, more travel requests will be inhibited
("PosExecute" will be blocked).
Designator
Data type
Information/possible settings