
4
Device control (DCTRL)
4.1
Device commands (C00002/x)
110
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
4.1.6
Reset error
The
= "1: On / start" device command acknowledges an existing error message if the
error cause has been eliminated and thus the error is no longer pending.
• After the reset (acknowledgement) of the current error, further errors may be pending which
must also be reset.
• The status determining error is displayed in
• The current error is displayed in
.
Tip!
An error message can also be acknowledged by activating the
Reset error
button in the
Diagnostics
tab.
Detailed information on error messages can be found in the "
" chapter.