Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
197
5
Motor control (MCTRL)
5.7
Sensorless vector control (SLVC)
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5.7.3
Basic settings
The following "Initial commissioning steps" must be performed to commission the sensorless vector
control:
Tip!
Information on the optimisation of the control mode and the adaptation to the real
application is provided in chapter "
We recommend to use the flying restart function for connecting/synchronising the inverter
to an already rotating drive system.
Parameterisable additional functions are described correspondingly in the chapter
"
Parameterisable additional functions
".
nTorqueMotLimit_a
| INT
Torque limitation in motor mode
• Scaling: 16384
≡
100 % M
max
(
)
• Setting range: 0 … +199.99 %
• If keypad control is performed: Parameterisable via
nTorqueGenLimit_a
| INT
Torque limitation in generator mode
• Scaling: 16384
≡
100 % M
max
(
)
• Setting range: -199.99 ... 0 %
• If keypad control is performed: Parameterisable via
Designator
DIS code | data type
Information/possible settings
Initial commissioning steps
1 Determine the motor control:
= "4: SLVC: Vector control"
2. Set the motor selection/motor data
• When selecting and parameterising the motor, the motor nameplate data and the equivalent circuit
diagram data are relevant. Detailed information can be found in the "
chapter.
Depending on the motor manufacturer, proceed as follows:
Lenze motor:
Selecting a motor from the motor catalogue in the
- or -
1.Set the motor nameplate data
2.
Automatic motor data identification
Third party manufacturer's motor:
1.Set the motor nameplate data
2.
Automatic motor data identification
or set known
equivalent circuit diagram data manually:
: Motor rotor resistance
: Motor stator resistance
: Motor stator leakage inductance
: Motor magnetising inductance
: Motor magnetising current
3. Define the type of control:
bTorquemodeOn
= FALSE:
Speed control with torque limitation
bTorquemodeOn
Torque control with speed limitation
4. Set the slip compensation (