Function library
17.2
System blocks | LS_PulseGenerator
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Parameters
Note!
The real length of the low or high level at the
bSquareWave
output is always 1 ms higher
than set in
. If "0 ms" is set, a level with a length of 1 ms is created
length, for instance, and if "1000 ms" is set, a level with a length of 1001 ms is created.
Parameters
Possible settings
Info
0
ms
60000 Length of the low level (break) + 1 ms
• For output
bSquareWave
• Lenze setting: 1000 ms
0
ms
60000 Length of the high level + 1 ms
• For output
bSquareWave
• Lenze setting: 1000 ms
(from version 06.00.00)
0
ms
60000 Delay of the status
bFirstCycleDone
• Lenze setting: 100 ms