15
Parameter reference
15.2
Parameter list
1046
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01057
C01058
C01059
C01060
Parameter | Name:
C01057 | L_CalcDiameter_1: Current diameter
Data type: UNSIGNED_32
Index: 23518
d
= 5BDE
h
From version 11.00.00
Display range
(min. value | unit | max. value)
0.000
mm
10000.000
Subcodes
Info
C01057/1
: Current diameter
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1000
Parameter | Name:
C01058 | L_PosCtrlLin 1-2: Limit stop
Data type: UNSIGNED_8
Index: 23517
d
= 5BDD
h
From version 11.00.00
Selection list
0 deactivated
1 activated
Subcodes
Lenze setting
Info
C01058/1
0: Deactivated
: Limit stop
C01058/2
0: Deactivated
: Limit stop
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C01059 | L_PosCtrlLin 1-2: Positioning behaviour
Data type: UNSIGNED_8
Index: 23516
d
= 5BDC
h
From version 11.00.00
Selection list
0 dnOut_p = 0
1 dnOut_p/nOut_v follow dnAct_p
2 dnOut_p/nOut_v follow dnSet_p
3 dnOut_p/nOut_v follow dnAct_p
(without limitation)
Subcodes
Lenze setting
Info
C01059/1
0: dnOut_p = 0
: Positioning behaviour
C01059/2
0: dnOut_p = 0
: Positioning behaviour
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C01060 | L_PosCtrlLin 1-2: Ramps
Data type: INTEGER_32
Index: 23515
d
= 5BDB
h
From version 11.00.00
Setting range
(min. value | unit | max. value)
0.010
s
130.000
Subcodes
Lenze setting
Info
C01060/1
1.000 s
: Deceleration of set position
C01060/2
1.000 s
: Acceleration ramp