C00965
C00966
C00967
Parameter | Name:
C00965 | Max. motor speed
Data type: UNSIGNED_16
Index: 23610
d
= 5C3A
h
From version 10.00.00
When the drive reaches the motor speed set here:
• The "Fault" error response takes place, i.e. the motor is shut down immediately.
" is entered into the logbook.
Setting range
(min. value | unit | max. value)
Lenze setting
50
rpm
65000
60000 rpm
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C00966 | VFC: Time const. slip comp.
Data type: UNSIGNED_16
Index: 23609
d
= 5C39
h
Filter time constant of the slip compensation for V/f characteristic control (
• The time constant of slip compensation serves to specify the dynamics of slip compensation for V/f characteristic
control without feedback.
• The lower the selected time constant, the higher the dynamic performance of the slip compensation.
Setting range
(min. value | unit | max. value)
Lenze setting
1
ms
6000 power-related (see
)
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C00967 | VFC: Frequency interpol. point n
Data type: INTEGER_16
Index: 23608
d
= 5C38
h
From version 04.00.00
Selection of the interpolation points (frequency values) for the V/f characteristic control (
) with user-
definable V/f characteristic (
= "10")
Setting range
(min. value | unit | max. value)
-2600.0
Hz
2600.0
Subcodes
Lenze setting
Info
C00967/1
-50.0 Hz
: Frequency interpol. point 1
C00967/2
-40.0 Hz
: Frequency interpol. point 2
C00967/3
-30.0 Hz
: Frequency interpol. point 3
C00967/4
-20.0 Hz
: Frequency interpol. point 4
C00967/5
-10.0 Hz
: Frequency interpol. point 5
C00967/6
0.0 Hz
: Frequency interpol. point 6
C00967/7
10.0 Hz
: Frequency interpol. point 7
C00967/8
20.0 Hz
: Frequency interpol. point 8
C00967/9
30.0 Hz
: Frequency interpol. point 9
C00967/10
40.0 Hz
: Frequency interpol. point 10
C00967/11
50.0 Hz
: Frequency interpol. point 11
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 10