
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
1254
17
Function library
17.1
Function blocks | L_AnalogSwitch_5
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
17.1.8
L_AnalogSwitch_5
This FB changes over between two analog input signals. The change-over is controlled via a boolean
input signal.
Inputs
Outputs
Designator
Data type
Information/possible settings
nIn1_a
INT
Input signal 1
nIn2_a
INT
Input signal 2
bSet
BOOL
Selection of the input signal for the output to
nOut_a
FALSE
nIn1_a
TRUE
nIn2_a
Designator
Data type
Value/meaning
nOut_a
INT
Output signal
/B$QDORJ6ZLWFKB
Q,QBD
Q2XWBD
Q,QBD
E6HW