Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
1089
15
Parameter reference
15.2
Parameter list
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01298
C01299
Parameter | Name:
C01298 | MCK: Operating mode change with profile no.
Data type: UNSIGNED_8
Index: 23277
d
= 5AED
h
FB
: Assignment of an operating mode to a profile
Selection list
Info
0 Op.Mode inputs
There will be no changed operating mode when the
profile is changed. Instead, the operating mode
requested "from outside" via the MCK control word
applies.
1 Speed follower
Change to the "Speed follower" mode
2 Homing
Change to the "Homing" mode
3 Manual jog
Change to the "Manual jog" mode
4 Positioning
Change to the "Positioning" mode
5 Stop
Change to the "Stop" mode
6 Position follower
Change to the "Position follower" mode
Subcodes
Lenze setting
Info
C01298/1
1: Speed follower
MCK operating mode at profile no. 0
• Selection of the operating mode for profile 0 at
L_MckCtrlInterface_1.
C01298/2
2: Homing
MCK operating mode at profile no. 1
• Selection of the operating mode for profile 1 at
L_MckCtrlInterface_1.
C01298/3
3: Manual jog
MCK operating mode at profile no. 2
• Selection of the operating mode for profile 2 at
L_MckCtrlInterface_1.
C01298/4
4: Positioning
MCK operating mode at profile no. 3...15
• Selection of the operating mode for profile 3 ... 15 at
L_MckCtrlInterface_1.
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C01299 | MCKI: Status MCKInterface
Data type: UNSIGNED_8
Index: 23276
d
= 5AEC
h
FB
: Status messages
Display area
(min. hex value | max. hex value)
0x00
0xFF
Value is bit-coded:
Info
Bit 0 InvalidOperationMode
Invalid operating mode selection
• 1
≡
The selected operating mode is not defined/
invalid.
Bit 1 InvalidPosMode
Invalid positioning mode selection
• 1
≡
The selected positioning mode is not defined/
invalid.
Bit 2 InvalidProfileNo
Invalid profile number selection
• 1
≡
The selected profile number refers to a profile data
set that does not exist.
Bit 3
Reserved