C00003
C00005
Parameter | Name:
C00003 | Status of last device command
Data type: UNSIGNED_8
Index: 24572
d
= 5FFC
h
Status of the device command executed last (
).
Note:
Before switching off the supply voltage after carrying out a device command, check whether the device command
has been carried out successfully via the status display!
:
Selection list
(read only)
Info
0 Successful
Device command has been executed successfully.
1 Command unknown
Device command implausible or unknown to the system.
2 Password protection
Unauthorised access for requested device command.
3 Time-out
Device command could not be processed in the defined
time (timeout).
4 System fault
5 Command server assigned
6 Controller inhibit required
7 unexpected controller inhibit
10 Memory module binding error
11 Password too short
12 Wrong password
13 Password already set
14 Password not assigned
15 Incorrect checksum
30 Incorrect pole position identification
31 Pole position identification started
without encoder
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C00005 | Application
Data type: UNSIGNED_16
Index: 24570
d
= 5FFA
h
Selection of the technology application
Selection list
(Lenze setting printed in bold)
Info
0 Wiring has changed
This display appears if the FB interconnection has been
changed in the application level using the FB Editor.