3
Commissioning
3.10
PC manual control
96
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
3.10.5
Positioning (relative or absolute)
Positioning means that a workpiece/tool or material is moved from a starting position to a defined
destination.
A change to the "Positioning" mode and a simultaneous selection of the positioning mode (relative
or absolute) is made by selecting the corresponding option on the
Positioning
tab:
• The profile parameters stored in the parameter set for the basic "Positioning" function are used:
You can find detailed information on the "Positioning" mode in the chapter entitled
"Basic drive functions" in the subchapter "
Parameters
Lenze setting
Info
Value Unit
Position
(
360.0000 units
Target position or distance to be traversed.
• With "Relative positioning": Distance to starting
position (current position).
• With "Absolute positioning": Distance to defined
zero position.
Velocity
(
360.0000 units/s
Maximum velocity at which the target is to be
approached.
Acceleration
(
720.0000 units/s
2
Specification of the maximum velocity variation which
is to be used for acceleration.
Deceleration
(
720.0000 units/s
2
Specification of the velocity variation which is to be
used for maximum deceleration to standstill.
S-ramp time
(
0.000 s
A profile is traversed with S-shaped ramps by defining
an S-ramp time for it.
Note!
In order that no complex travel movements occur, no switching to a sequence profile
takes place that has been set in the profile data!
You can find detailed information on entering profiles in the chapter entitled "Basic drive
functions", subchapter "