Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
507
8
Basic drive functions (MCK)
8.2
Internal interfaces | System block "LS_MotionControlKernel"
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
8.2.2
MCK status word
MCK status word 1 (wMotionState1)
Bit
Designation
Description
0
...
3
ActOpModeBit00
...
ActOpModeBit03
Active operating mode
Bit 3
Bit 2
Bit 1
Bit 0
0
0
0
0
0
0
0
1
0
0
1
0
0
0
1
1
0
1
0
0
0
1
0
1
StandBy (internal operating mode in the event of
quick stop, pulse inhibit, and DC-injection braking)
1
1
1
1
4 Busy
"1"
≡
Internal profile generation is active. A speed profile is being generated.
5 Done
"1"
≡
Generation of a speed profile with the selected position has been completed.
6 AcceleratingActive
"1"
≡
Profile generation phase is in the acceleration process.
7 ConstSpeedDuty
"1"
≡
Profile generation phase at constant speed active.
8 DeceleratingActive
"1"
≡
Profile generation phase is in the deceleration process.
9 S_ShapingActive
From version 12.00.00:
"1"
≡
Rounding during acceleration/deceleration active.
10 Pos. HW-Limit
Detected
"1"
≡
Positive limit switch has triggered.
• Reset only possible via"Manual jog" mode!
11 Neg. HW-Limit
Detected
"1"
≡
Negative limit switch has triggered.
• Reset only possible via"Manual jog" mode!
12 HomPosDone
"1"
≡
Homing has been completed.
13 HomPosAvailable
"1"
≡
The home position has been detected and is known in the drive.
14 Pos. SW limit
detected
"1"
≡
Positive software limit position overtravelled.
15 Neg. SW limit
detected
"1"
≡
Negative software limit position overtravelled.
Note!
The internal "
" operating mode is assumed if controller inhibit, pulse inhibit,
quick stop and/or DC-injection braking are activated.
• In this operating mode, no setpoint generation takes place through the
Motion
Control Kernel
.
• If the holding brake control sets a controller inhibit when the holding brake is closed,
the internal "StandBy" operating mode is not assumed.