Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
1077
15
Parameter reference
15.2
Parameter list
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01233
C01234
C01235
Parameter | Name:
C01233 | MCK: Manual jog S-ramp time
Data type: UNSIGNED_16
Index: 23342
d
= 5B2E
h
S-ramp time for manual jog
• Setting "0 s"
≡
no rounding
Setting range
(min. value | unit | max. value)
0.000
s
10.000
Subcodes
Lenze setting
Info
C01233/1
0.000 s
Manual jog: S-ramp time
• S-ramp time for the manual speed ramps.
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1000
Parameter | Name:
C01234 | MCK: Manual jog breakpoints
Data type: INTEGER_32
Index: 23341
d
= 5B2D
h
Breakpoint positions for manual jog
• The drive stops at the parameterised positions if these are located in the manual jog direction and the
approaching of the breakpoints is switched on in
via bit 0.
Setting range
(min. value | unit | max. value)
-214748.3647
unit
214748.3647
Subcodes
Lenze setting
Info
C01234/1
0.0000 unit
Manual jog: Breakpoint 1
C01234/2
0.0000 unit
Manual jog: Breakpoint 2
C01234/3
0.0000 unit
Manual jog: Breakpoint 3
C01234/4
0.0000 unit
Manual jog: Breakpoint 4
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 10000
Parameter | Name:
C01235 | MCK: Manual jog waiting times
Data type: UNSIGNED_16
Index: 23340
d
= 5B2C
h
Waiting times for manual jog
Setting range
(min. value | unit | max. value)
0.000
s
65.000
Subcodes
Lenze setting
Info
C01235/1
5.000 s
Manual jog: Waiting time 2nd speed
• Time after which the first manual speed (
accelerated to the second manual speed (
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1000