Working with the FB Editor
16.2
User interface
1202
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
"Application interconnection" level
This level displays the interconnection of the application selected in
in detail. All function
blocks used in the application and the system blocks which provide the interfaces to the drive and
motor interface and to the MotionControlKernel (MCK) are displayed with their connections.
• The interconnection of the I/Os of the inverter with the inputs and outputs of the application is
masked out in this level.
[16-6] Schematic diagram of "Application interconnection"
Tip!
Every application block features so-called "free inputs and outputs" which you can use to
transfer signals from the I/O level to the application level and vice versa.
• In the Lenze setting, these connectors are hidden in the function block editor.
• These connections can be shown via the
Connector visibilities
command in the
Context
menu
of the application block.
"Free interconnection" level
This level serves to implement an individual drive solution for the device versions "StateLine C"
(from version 12.00.00 and »Engineer« V2.17)
, "HighLine C" and "TopLine C".
Note!
When you select the "Free interconnection" level for the first time, you are prompted to
confirm whether the interconnection from the I/O level and the application level are to
be combined and copied into this level.
When you confirm this confirmation prompt with
Yes
, the I/O level and the application
level are not available anymore. This action can only be undone by resetting the
application to a predefined Lenze application!