Parameter reference
15.2
Parameter list
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00002/23
0: Off / ready
Identify motor parameters
• This device command serves to carry out automatic
motor parameter identification.
• The device command is only executed when the
inverter is in the "SwitchedOn" status.
• In order to identify the motor parameters, the
inverter must be enabled after this device command.
•
From version 10.00.00 onwards
, the identification
Automatic motor parameter identification
C00002/24
0: Off / ready
Reserved
C00002/25
0: Off / ready
Reserved
C00002/26
0: Off / ready
CAN reset node
• Reinitialise "CAN on board" interface.
• Required when changing the baud rate, node address,
or identifiers.
C00002/27
0: Off / ready
Device search function
•
From version 06.00.00
• This device command serves to optically locate an
inverter connected online (e.g. for maintenance
work).
C00002/28
0: Off / ready
Check MasterPin
•
From version 06.00.00
Unlocking the inverter with a MasterPin
C00002/29
0: Off / ready
Set binding ID
•
From version 06.00.00
C00002/30
0: Off / ready
Delete binding ID
•
From version 06.00.00
C00002/31
0: Off / ready
Set password
•
From version 06.00.00
C00002/32
0: Off / ready
Check password
•
From version 06.00.00
C00002/33
0: Off / ready
Delete password
•
From version 06.00.00
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C00002 | Device command
Data type: UNSIGNED_8
Index: 24573
d
= 5FFD
h