Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
597
8
Basic drive functions (MCK)
8.9
Stop
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
8.9
Stop
If the "normal stop" operating mode is active, the drive is brought to a standstill with a
parameterisable deceleration ramp.
8.9.1
Parameter setting
Short overview of parameters for "Normal stop" operating mode:
8.9.2
Requesting the operating mode
Request for "Normal stop" operating mode by means of the
If the
MCKInterface
is connected upstream to the
Motion Control Kernel
and if the operating mode
is requested at the
wOperationMode
and
bOperationMode_1...8
process
inputs are available.
Parameters
Info
Lenze setting
Value Unit
Normal stop: Deceleration
720.0000 units/s2
Stop: S-ramp time
0.000 s
MCK control word
Bit 31
...
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
OpMode_Bit3
OpMode_Bit2
OpMode_Bit1
OpMode_Bit0
X
...
X
0
1
0
0
X = Status not significant