17.2
System blocks | LS_DisFree_a
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
17.2.9.1
Display of internal process factors in application units
This function extension is available from version 06.00.00!
In addition to the display in percent in
, for the first four analog signals
nDis1_a
...
nDis4_a
the configurable display parameters
are provided. Via these
display parameters, internal process variables can be displayed, e.g. on the keypad, with an
individual scaling and an individual unit (from keypad version 02.01).
Configuration of the display parameters (
):
[17-79] Formula for scaling the display
Example 1:
• Input variable
nDis1_a
= 100 %
• Offset 1 (
) = 0 %
• Display factor 1 (
) = 123.45
• Text 1 (
) = "parts"
Example 2:
• Input variable
nDis2_a
= 40 %
• Offset 2 (
) = 35 %
• Display factor 2 (
) = 20
• Text 2 (
) = "kg"
Parameters
Possible settings
Info
-199.99
%
199.99 Offset 1 ... 4
• See formula
• Lenze setting: 0.00 %
-65536.0000
65536.0000 Display factor 1 ... 4
• Scaling of the input variable for
the display.
• See formula
• Lenze setting: 1.0000
String
(max. 7 digits)
Text 1 ... 4
• For each display value, an
individual unit (e.g. "parts") can be
set.
User unit 1
nDis1_a [%] Offset 1 [%]
+
100 [%]
--------------------------------------------------------------------
Display factor 1 [text 1]
⋅
=
User unit 1
100 [%] 0 [%]
+
100 [%]
---------------------------------------
123.45 [parts]
⋅
123.45 parts
=
=
User unit 2
40 [%] 35 [%]
+
100 [%]
---------------------------------------
20 [kg]
⋅
15.00 kg
=
=