Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
829
15
Parameter reference
15.2
Parameter list
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00074
C00075
C00076
C00077
Parameter | Name:
C00074 | Reset time Imax/M controller
Data type: UNSIGNED_16
Index: 24501
d
= 5FB5
h
Reset time Ti of certain controllers for different motor control modes
Setting range
(min. value | unit | max. value)
0
ms
9990
Subcodes
Lenze setting
Info
C00074/1
power-related (see
) ms
: Ti Imax controller
C00074/2
power-related (see
) ms
: Ti torque controller
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C00075 | Vp current controller
Data type: UNSIGNED_16
Index: 24500
d
= 5FB4
h
Gain factor Vp of the current controller for servo control (
) and certain inverter functions (parameter
identification, flying restart circuit)
• After the motor to be used has been selected from the motor catalogue, the suitable value can be entered
automatically.
Setting range
(min. value | unit | max. value)
Lenze setting
0.00
V/A
500.00 power-related (see
)
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 100
Parameter | Name:
C00076 | Ti current controller
Data type: UNSIGNED_16
Index: 24499
d
= 5FB3
h
Reset time Ti of the current controller for servo control (
) and certain inverter functions (parameter identification,
flying restart circuit)
• After the motor to be used has been selected from the motor catalogue, the suitable value can be entered
automatically.
Setting range
(min. value | unit | max. value)
Lenze setting
0.00
ms
500.00 power-related (see
)
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 100
Parameter | Name:
C00077 | SC: Vp field controller
Data type: UNSIGNED_16
Index: 24498
d
= 5FB2
h
Gain factor Vp of the field controller for servo control (
• After the motor to be used has been selected from the motor catalogue, the suitable value can be entered
automatically.
Setting range
(min. value | unit | max. value)
Lenze setting
0.00
500.00 power-related (see
)
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 100