Working with the FB Editor
16.3
Using the FB Editor as "Viewer"
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
16.3
Using the FB Editor as "Viewer"
The main purpose of the FB Editor is the individual configuration of the selected technology
application. However, you can also use the FB Editor to
• make a diagnosis of the application (when an online connection has been established),
• get a better understanding for the operating mode of the application,
• use the interconnection as an alternative parameterisation access.
Diagnostics of the application
When an online connection to the inverter has been established, the current values are displayed at
the inputs and outputs of the objects:
• Process-scaled signals can be scaled in a "user-defined" way for easy diagnostics in the FB Editor.
Getting a better understanding for the operating mode of the application
Make yourself familiar with the signal flow of the interconnection to get a better understanding of
the operating mode of the application or individual functional areas.
• The
symbol in the head of the block or the
Help
command in the
context menu
for the block
serve to open the online help for the block.
Using the interconnection as an alternative parameterisation access
• The
icon in the head of the module, a double-click on the module, or the
Parameter...
command in the
Context menu
of the module serve to open the parameterisation dialog or the
parameter list for the module.
"