17
Function library
17.1
Function blocks | L_PhiIntegrator_1
1479
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
17.1.139.1 Function
The
nSet_v
input value is evaluated, integrated and output as 16-bit value (
nOut16
) and 32-bit
value
dnOut32_p
) with the gearbox factors
wGearNum
and
wGearDenom
.
• Evaluation of the gearbox factor is remainder considered.
• A positive or negative overflow of the integrator is signalised by a TRUE signal (for a task cycle)
at the
bOvfl16
output for the
nOut16
output or at the
bOvfl32
output for the
dnOut32_p
output.
[17-65] Signal characteristic
nOut16
nOut16 nSet_v wGearNum
wGearDenom
------------------------------------
⋅
+
=
dnOut32_p
dnOut32_p nSet_v wGearNum
wGearDenom
------------------------------------
⋅
+
=
1
2
3
4 5
6
Signal
t
1x Taskcycl
1x Taskcycl
1x Taskcycl
1x Taskcycl
1x Taskcycl
7 8
9
10
dn
_p
t 4
TPPosition
dnTPPosition_p
t 7
2
-1
15/ 31
0
dnLoadVal_p
-2
15/ 31
bTPReceived
bLoad
bReset
bOvflxx