15
Parameter reference
15.2
Parameter list
890
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00410
C00411
C00412
Parameter | Name:
C00410 | L_SignalMonitor_a: Signal sources
Data type: UNSIGNED_16
Index: 24165
d
= 5E65
h
The
FB: Selection of the signal sources
Selection list
See
selection list - analog signals
Subcodes
Lenze setting
Info
C00410/1
0: Not connected
Signal source for output
nOut1_a
C00410/2
0: Not connected
Signal source for output
nOut2_a
C00410/3
0: Not connected
Signal source for output
nOut3_a
C00410/4
0: Not connected
Signal source for output
nOut4_a
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C00411 | L_SignalMonitor_b: Signal sources
Data type: UNSIGNED_16
Index: 24164
d
= 5E64
h
The
FB: Selection of the signal sources
Selection list
See
selection list - digital signals
Subcodes
Lenze setting
Info
C00411/1
0: Not connected
Signal source for output
bOut1
C00411/2
0: Not connected
Signal source for output
bOut2
C00411/3
0: Not connected
Signal source for output
bOut3
C00411/4
0: Not connected
Signal source for output
bOut4
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C00412 | L_SignalMonitor_b: Inversion
Data type: UNSIGNED_8
Index: 24163
d
= 5E63
h
The
FB: Inversion of the binary outputs
Setting range
(min. hex value | max. hex value)
Lenze setting
0x00
0xFF
0x00
(decimal: 0)
Value is bit-coded: (
= bit set)
Info
Bit 0
bOut1 inverted
Bit set = inversion active
Bit 1
bOut2 inverted
Bit 2
bOut3 inverted
Bit 3
bOut4 inverted
Bit 4
Reserved
Bit 5
Reserved
Bit 6
Reserved
Bit 7
Reserved
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT