15
Parameter reference
15.2
Parameter list
1136
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02589
C02593
Parameter | Name:
C02589 | Holding brake: Time system
Data type: UNSIGNED_16
Index: 21986
d
= 55E2
h
Operating times of the holding brake
• The electromechanical delay times of the holding brake are specified in the data sheets or on the holding brake
nameplate.
Setting range
(min. value | unit | max. value)
0
ms
60000
Subcodes
Lenze setting
Info
C02589/1
100 ms
Holding brake: Application time
• Time in which the holding brake is completely applied
from the beginning of control and in which the
controller is inhibited.
C02589/2
100 ms
Holding brake: Release time
• Time in which the holding brake is completely
released from the beginning of control.
C02589/3
100 ms
Holding brake: Waiting time status
• Time after which all transient reactions are
completed and the switching status of the holding
brake is stable. Beginning of monitoring the feedback
signal for the switching status of the holding brake.
C02589/4
0 ms
Holding brake: Ramp time FF ctrl
•
From version 06.00.00
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C02593 | Holding brake: Activation time
Data type: UNSIGNED_32
Index: 21982
d
= 55DE
h
Time parameter for the delay of trigger signals of the holding brake control
Setting range
(min. value | unit | max. value)
0.000
s
3600.000
Subcodes
Lenze setting
Info
C02593/1
0.000 s
Holding brake: Actual value monitoring
• Time in which the actual value is supposed to reach
the threshold for closing the brake if the setpoint has
already reached the threshold.
• Time > 0 s: If the actual speed value has not reached
the threshold within the time for brake application,
the holding brake is applied by control.
• Time = 0 s: The brake is only applied by control when
the actual speed has reached the application
threshold.
C02593/2
0.000 s
Holding brake: Application delay
• Time by which the control process for holding brake
application is delayed. The time expires when the
speed setpoint has reached the switching threshold
for application.
• With positioning processes, a continuous application
and release of the holding brake can thus be
suppressed for the set time.
C02593/3
0.000 s
Holding brake: Reserved
C02593/4
0.000 s
Holding brake: Reserved
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1000