Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
1372
17
Function library
17.1
Function blocks | L_DigitalLogic_2
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
17.1.78
L_DigitalLogic_2
This FB provides a binary output signal created by a logic operation of the input signals. Optionally,
one of the constant binary values independent from the input signals can be output.
• Output of a constant binary value
• AND operation of the inputs
• OR operation of the inputs
• Output depending on the combination of the input signals
Inputs
Outputs
Designator
Data type
Information/possible settings
bIn1
BOOL
Input signal 1
bIn2
BOOL
Input signal 2
bIn3
BOOL
Input signal 3
Designator
Data type
Value/meaning
bOut
BOOL
Output signal 1
bOut2
BOOL
Output signal 2
•
bOut2 is available from version 16.00.00 onwards
bOut3
BOOL
Output signal 3
•
bOut3 is available from version 16.00.00 onwards
/B'LJLWDO/RJLFB
E,Q
E,Q
E,Q
E2XW
!
&
&
&
&
&
E2XW
!
&
&
&
&
&
E2XW
!
&
&
&
&
&