Address
Designation
Default setting
Data type
Factor A
M
Cycle length
360.0000
I32
10000
C
Feed constant
360.0000
I32
10000
C
Gearbox factor - nominator
1
U32
1
C
Gearbox factor - denominator
1
U32
1
C
Motor mounting direction
0
BOOLEAN
C
Load moment of inertia
0.00 kg cm²
I32
100
-
Max. velocity
0.0000
I32
10000
-
Max. acceleration
0.00
I32
100
-
Max. jerk
0.00
I32
100
-
Application quick stop - deceleration
3600.00
I32
100
-
Application quick stop - jerk
0.00
I32
100
-
Enable software limit switches
0
BOOLEAN
-
Software limit switch positive
0.0000
I32
10000
-
Software limit switch negative
0.0000
I32
10000
-
Action after "software limit switch reached"
Stop at software limit switch [1]
U16
-
Following error monitoring
1
BOOLEAN
-
Following error: Warning threshold
180.0000
I32
10000
-
Following error: Error threshold
360.0000
I32
10000
-
Actual following error
- (Read only)
I32
10000
X
Max. following error
- (Read only)
I32
10000
X
Response to following error
Fault > Application quick stop > Quick
stop [20]
U8
-
Homing mode
SetPositionDirect [0]
I16
-
Action after "Home position detected"
Stop positioning [0]
I16
-
Homing: Set position
0.0000
I32
10000
-
Homing: Set position
360.0000
I32
10000
-
Homing : Velocity 2
0.0000
I32
10000
-
Homing : Acceleration 1
720.00
I32
100
-
Homing : Acceleration 2
360.00
I32
100
-
Homing : Jerk
7200.00
I32
100
-
Homing : Torque limit
0.10 Nm
I32
100
-
Homing : Blocking time
1.000 s
I32
1000
-
Homing : Touch probe configuration
TP1 - positive edge [1]
U32
-
Keep home position after mains switching
0
BOOLEAN
-
Max. angle of rotation after mains switching
0.0000000000 °
I32
1
-
Home position
0.0000
I32
10000
-
Default control mode
Position control via motor encoder [0]
U16
C
Actual control mode
- (Read only)
U16
X
Load encoder selection
[-]
STRING[80]
C
Position controller gain
20.0000 1/s
I32
10000
-
Load encoder output limit
100000.0000
I32
10000
-
Position controller output
- (Read only)
I32
10000
X
Response to hardware limit switch error
Fault > Application quick stop > Quick
stop [19]
U8
-
Response to software limit switch error
Fault > Application quick stop > Quick
stop [19]
U8
-
Response to error "max. values exceeded"
Warning [2]
U8
-
Response to inverter disable during operation
No response [0]
U8
-
Positive torque limit
200.0 %
I16
10
-
Negative torque limit
200.0 %
I16
10
-
Position window size
0.0000
I32
10000
-
Position window dwell time
0.000 s
I32
1000
-
Standstill window size (motor encoder)
0.0000
I32
10000
-
Modulo positioning tolerance window
0.0000
I32
10000
-
* Default setting depending on the size.
Appendix
Parameter attribute list
486
Содержание i950 Series
Страница 1: ...Inverters i950 servo inverters Commissioning EN ...
Страница 2: ......
Страница 312: ...15 Configure engineering port The given path leads you to the engineering port Configure engineering port 312 ...
Страница 397: ...19 Safety functions Supported safety functions for Basic Safety STO 4Safe Torque Off STO 398 Safety functions 397 ...
Страница 497: ......
Страница 498: ......
Страница 499: ......