Address
Name / setting range / [default setting]
Info
0x4001
Interface selection
Selecting the interface determines the interface that receives the signals.
0 Fieldbus network
Control of the application via the fieldbus.
1 Systembus network
Activation of the application via the system bus.
0x500B:011
Actual velocity
•
Read only
The current speed value is resolved with 4 decimal positions.
0x5020:009
Reference velocity for analog input 1
0.0000 ... [500.0000] ... 214748.3647
The reference speed for the percentage value of the analog input.
0x5020:014
Master value source
•
Setting can only be changed if the inverter is inhibi-
ted.
0 System bus
The system bus provides the external master velocity value.
1 Load encoder
The signal from the load encoder interface is taken as the master veloc-
ity value.
2 Virtual master
The virtual master, whose setpoint velocity comes from the Set virtual
master velocity PDO, serves as master value master.
3 Analog input 1
0x5021:152
System bus diagnostics: Velocity (input value)
•
Read only
Speed conductivity
Configuring the "Sync and Correction" TA
Master value sources
Virtual master
105