M
Inductance grid points (y) Lss saturation characteris-
tic: y8 = L08 (x = 42.75 %)
62 %
U16
1
-
Inductance grid points (y) Lss saturation characteris-
tic: y9 = L09 (x = 50.00 %)
55 %
U16
1
-
Inductance grid points (y) Lss saturation characteris-
tic: y10 = L10 (x = 56.25 %)
50 %
U16
1
-
Inductance grid points (y) Lss saturation characteris-
tic: y11 = L11 (x = 62.50 %)
46 %
U16
1
-
Inductance grid points (y) Lss saturation characteris-
tic: y12 = L12 (x = 68.75 %)
43 %
U16
1
-
Inductance grid points (y) Lss saturation characteris-
tic: y13 = L13 (x = 75.00 %)
42 %
U16
1
-
Inductance grid points (y) Lss saturation characteris-
tic: y14 = L14 (x = 81.25 %)
41 %
U16
1
-
Inductance grid points (y) Lss saturation characteris-
tic: y15 = L15 (x = 87.50 %)
41 %
U16
1
-
Inductance grid points (y) Lss saturation characteris-
tic: y16 = L16 (x = 93.25 %)
41 %
U16
1
-
Inductance grid points (y) Lss saturation characteris-
tic: y17 = L17 (x = 100.00 %)
41 %
U16
1
-
Inductance grid points (y) Lss saturation characteris-
tic: Activation Lss saturation characteristic
Adjustment on [1]
U16
-
Reference for current grid points (x) Lss saturation
characteristic
5.4 A
U16
10
-
Grid points for magnet characteristic (current): x1 =
i01/iN
0 %
U16
1
-
Grid points for magnet characteristic (current): y1 =
kT01/kTN
100 %
U16
1
-
Grid points for magnet characteristic (current): x2 =
i02/iN
100 %
U16
1
-
Grid points for magnet characteristic (current): y2 =
kT02/kTN
100 %
U16
1
-
Grid points for magnet characteristic (current): x3 =
i03/iN
200 %
U16
1
-
Grid points for magnet characteristic (current): y3 =
kT03/kTN
100 %
U16
1
-
Grid points for magnet characteristic (current): x4 =
i04/iN
415 %
U16
1
-
Grid points for magnet characteristic (current): y4 =
kT04/kTN
72 %
U16
1
-
Inductance grid points (y) Lh saturation characteris-
tic: y1 = L01 (x = 0.00 %)
118 %
U16
1
-
Inductance grid points (y) Lh saturation characteris-
tic: y2 = L02 (x = 6.25 %)
118 %
U16
1
-
Inductance grid points (y) Lh saturation characteris-
tic: y3 = L03 (x = 12.50 %)
118 %
U16
1
-
Inductance grid points (y) Lh saturation characteris-
tic: y4 = L04 (x = 18.75 %)
117 %
U16
1
-
Inductance grid points (y) Lh saturation characteris-
tic: y5 = L05 (x = 25.00 %)
116 %
U16
1
-
Inductance grid points (y) Lh saturation characteris-
tic: y6 = L06 (x = 31.25 %)
114 %
U16
1
-
Inductance grid points (y) Lh saturation characteris-
tic: y7 = L07 (x = 37.50 %)
111 %
U16
1
-
Inductance grid points (y) Lh saturation characteris-
tic: y8 = L08 (x = 43.75 %)
107 %
U16
1
-
Inductance grid points (y) Lh saturation characteris-
tic: y9 = L09 (x = 50.00 %)
100 %
U16
1
-
* Default setting depending on the size.
Appendix
Parameter attribute list
478
Содержание i950 Series
Страница 1: ...Inverters i950 servo inverters Commissioning EN ...
Страница 2: ......
Страница 312: ...15 Configure engineering port The given path leads you to the engineering port Configure engineering port 312 ...
Страница 397: ...19 Safety functions Supported safety functions for Basic Safety STO 4Safe Torque Off STO 398 Safety functions 397 ...
Страница 497: ......
Страница 498: ......
Страница 499: ......