Basic setting
This chapter contains the most frequently used functions and settings to adapt the inverter to
a simple application based on the default setting.
5.1
Device name
Parameter
Address
Name / setting range / [default setting]
Info
0x2001
Device name
["Device"]
Any device name (e.g. "Wheel drive") can be set in this object for the
purpose of device identification.
5.2
Mains voltage
The rated mains voltage set for the inverter has an impact on the operating range of the inver-
ter.
Parameter
Address
Name / setting range / [default setting]
Info
0x2540:001
Mains settings: Rated mains voltage
Selection of the mains voltage for actuating the inverter.
0 230 Veff
1 400 Veff
2 480 Veff
4 60 V (setting-up operation)
10 230 Veff/reduced LU level
11 400 Veff/reduced LU level
12 480 Veff/reduced LU level
0x2540:002
Mains settings: Undervoltage warning threshold
0 ... [430] ... 800 V
Setting of the warning threshold for monitoring DC bus undervoltage.
•
If the DC bus voltage falls below the threshold set, the inverter out-
puts a warning.
•
The warning is reset with a hysteresis of 10 V.
0x2540:003
Mains settings: Undervoltage error threshold
•
Read only: x V
Display of the fixed error threshold for monitoring DC bus undervoltage.
•
If the DC-bus voltage falls below the threshold displayed, the "Error"
response is triggered.
0x2540:004
Mains settings: Undervoltage reset threshold
•
Read only: x V
Display of the fixed reset threshold for monitoring DC bus undervoltage.
0x2540:005
Mains settings: Overvoltage warning threshold
0 ... [795] ... 800 V
Setting of the warning threshold for monitoring DC bus overvoltage.
•
If the DC bus voltage exceeds the threshold set, the inverter outputs a
warning.
•
The warning is reset with a hysteresis of 10 V.
0x2540:006
Mains settings: Overvoltage error threshold
•
Read only: x V
Display of the fixed error threshold for monitoring the DC bus overvolt-
age.
•
If the DC-bus voltage exceeds the threshold displayed, the "Fault"
response is triggered.
0x2540:007
Mains settings: Overvoltage reset threshold
•
Read only: x V
Display of the fixed reset threshold for monitoring DC bus overvoltage.
0x2540:008
Mains settings: DC link voltage critical
•
Read only
Display of value "1": the DC-bus voltage has reached a critical value.
5.3
Function assignment of the inputs and outputs (default setting)
I/O extensions and control connections
" describes the assignment of functions to inputs and
outputs.
Basic setting
Function assignment of the inputs and outputs (default setting)
37
Содержание i950 Series
Страница 1: ...Inverters i950 servo inverters Commissioning EN ...
Страница 2: ......
Страница 312: ...15 Configure engineering port The given path leads you to the engineering port Configure engineering port 312 ...
Страница 397: ...19 Safety functions Supported safety functions for Basic Safety STO 4Safe Torque Off STO 398 Safety functions 397 ...
Страница 497: ......
Страница 498: ......
Страница 499: ......