Address
Name / setting range / [default setting]
Info
0x500A:080
Homing : Touch probe configuration
0 External source
1 TP1 - positive edge
2 TP1 - negative edge
3 TP1 - any edge
4 TP1 - zero pulse
11 TP2 - positive edge
12 TP2 - negative edge
13 TP2 - any edge
14 TP2 - zero pulse
21 TP3 - positive edge
22 TP3 - negative edge
23 TP3 - any edge
24 TP3 - zero pulse
31 TP4 - positive edge
32 TP4 - negative edge
33 TP4 - any edge
34 TP4 - zero pulse
0x500A:084
Home position
-214748.3648 ... [0.0000] ... 214748.3647
Technology application (TA) basic settings
Motion settings
Homing
60