Address
Designation
Default setting
Data type
Factor A
M
Inertia settings: Motor moment of inertia
0.14 kg cm²
U32
100
-
Inertia settings: Load moment of inertia
0.00 kg cm²
U32
100
-
Inertia settings: Coupling
Stiff [0]
U8
-
Inertia settings: Mechanical natural frequency
0.0 Hz
U16
10
-
Inertia settings: Load moment of inertia (elastic cou-
pled)
0.00 kg cm²
U32
100
-
Switching frequency
4 kHz variable / drive-optimised [1]
U8
-
Current controller feedforward control
Disable [0]
U8
-
Current controller parameters: Gain
148.21 V/A
U32
100
-
Current controller parameters: Reset time
3.77 ms
U32
100
-
Current setpoint filter time
0.00 ms
U16
100
-
Torque setpoint notch filter: Frequency notch filter 1 200.0 Hz
U16
10
-
Torque setpoint notch filter: Bandwidth notch filter
1
20.0 Hz
U16
10
-
Torque setpoint notch filter: Damping notch filter 1 0 dB
U8
1
-
Torque setpoint notch filter: Frequency notch filter 2 400.0 Hz
U16
10
-
Torque setpoint notch filter: Bandwidth notch filter
2
40.0 Hz
U16
10
-
Torque setpoint notch filter: Damping notch filter 2 0 dB
U8
1
-
Torque setpoint jerk limitation
400.0 %
U16
10
-
Speed limitation: Upper speed limit
0 rpm
I32
480000
/2
31
-
●
Speed limitation: Lower speed limit
0 rpm
I32
480000
/2
31
-
●
Inverter characteristic: Value y1
0.00 V
U16
100
-
Inverter characteristic: Value y2
0.00 V
U16
100
-
Inverter characteristic: Value y3
0.00 V
U16
100
-
Inverter characteristic: Value y4
0.00 V
U16
100
-
Inverter characteristic: Value y5
0.00 V
U16
100
-
Inverter characteristic: Value y6
0.00 V
U16
100
-
Inverter characteristic: Value y7
0.00 V
U16
100
-
Inverter characteristic: Value y8
0.00 V
U16
100
-
Inverter characteristic: Value y9
0.00 V
U16
100
-
Inverter characteristic: Value y10
0.00 V
U16
100
-
Inverter characteristic: Value y11
0.00 V
U16
100
-
Inverter characteristic: Value y12
0.00 V
U16
100
-
Inverter characteristic: Value y13
0.00 V
U16
100
-
Inverter characteristic: Value y14
0.00 V
U16
100
-
Inverter characteristic: Value y15
0.00 V
U16
100
-
Inverter characteristic: Value y16
0.00 V
U16
100
-
Inverter characteristic: Value y17
0.00 V
U16
100
-
Torque limits offset: Torque offset
0.0 %
I16
10
-
Torque limits offset: Resulting positive torque limit
x.x % (Read only)
I16
10
X
Torque limits offset: Resulting negative torque limit x.x % (Read only)
I16
10
X
Position controller gain
28.40 Hz
U32
100
-
Position controller gain adaption
100.00 %
U16
100
-
●
Position controller output signal limitation
480000.00 rpm
U32
480000
/2
31
-
●
Actual position start value
0 pos. unit
I32
1
-
●
Mode for setting the actual position
Absolute [0]
U8
-
Resulting gain adaption
x.xx % (Read only)
U32
100
X
Field controller settings: Gain
165.84 A/Vs
U32
100
-
Field controller settings: Reset time
15.1 ms
U16
10
-
Field weakening controller settings: Gain (ASM)
0.000 Vs/V
U32
1000
-
* Default setting depending on the size.
Appendix
Parameter attribute list
475
Содержание i950 Series
Страница 1: ...Inverters i950 servo inverters Commissioning EN ...
Страница 2: ......
Страница 312: ...15 Configure engineering port The given path leads you to the engineering port Configure engineering port 312 ...
Страница 397: ...19 Safety functions Supported safety functions for Basic Safety STO 4Safe Torque Off STO 398 Safety functions 397 ...
Страница 497: ......
Страница 498: ......
Страница 499: ......