Address
Name / setting range / [default setting]
Info
0x2451:003
Engineering port settings: Gateway
0.0.0.0 ... [0.0.0.0] ... 255.255.255.255
Setting of the gateway address.
Example:
The setting 276344004 corresponds to the gateway address
196.172.120.16.
•
276344004 = 0x1078ACC4
à
0xC4.0xAC.0x78.0x10 = 196.172.120.16
0x2451:004
Engineering port settings: DHCP
Use (enable) of the Dynamic Host Configuration Protocol (DHCP).
0 Disabled
1 Enabled
0x245B:001
System time: Time base
0 NTP
1 EtherCAT distributed clock
2 Manual input
0x245B:002
System time: Current time
0 ... [] ... 18446744073709551615 ns
15.2
NTP server addresses
Parameter
Address
Name / setting range / [default setting]
Info
0x245A:001
NTP server addresses: Activate NTP server addresses
0 No action/no error
1 Restart with current values
10 In progress
11 Action cancelled
12 Fault
0x245A:002
NTP server addresses: NTP server address 1
0.0.0.0 ... [0.0.0.0] ... 255.255.255.255
0x245A:003
NTP server addresses: NTP server address 2
0.0.0.0 ... [0.0.0.0] ... 255.255.255.255
0x245A:004
NTP server addresses: NTP server address 3
0.0.0.0 ... [0.0.0.0] ... 255.255.255.255
0x245A:005
NTP server addresses: NTP server address 4
0.0.0.0 ... [0.0.0.0] ... 255.255.255.255
15.3
Diagnostics
The network settings can be diagnosed as follows:
Parameter
Address
Name / setting range / [default setting]
Info
0x2452:001
Active engineering port settings: IP address
•
Read only
Display of the active IP address.
0x2452:002
Active engineering port settings: Subnet
•
Read only
Display of the active subnet mask.
0x2452:003
Active engineering port settings: Gateway
•
Read only
Display of the active gateway address.
0x2452:005
Active engineering port settings: MAC address
•
Read only
Display of the MAC-ID.
Configure engineering port
Diagnostics
314
Содержание i950 Series
Страница 1: ...Inverters i950 servo inverters Commissioning EN ...
Страница 2: ......
Страница 312: ...15 Configure engineering port The given path leads you to the engineering port Configure engineering port 312 ...
Страница 397: ...19 Safety functions Supported safety functions for Basic Safety STO 4Safe Torque Off STO 398 Safety functions 397 ...
Страница 497: ......
Страница 498: ......
Страница 499: ......