16.1.6
Device states
( CiA: Statusword ) displays the current device status of the inverter.
Device status
Bit pattern in the CiA 402 status word (
)
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Warning is
active
Operation
inhibited
Quick stop
active
DC bus
ready for
operation
Fault active Operation
enabled
Switched
on
Ready to
switch on
X
1
X
X
0
0
0
0
X
1
X
X
0
0
0
0
X
1
1
X
0
0
0
1
X
1
1
X
0
0
1
1
X
0
0
X
0
1
1
1
X
0
1
X
0
1
1
1
X
0
X
X
1
1
1
1
X
1
X
X
1
0
0
0
X = state is not relevant
Status bit 7: "Warning active"
Status bit 7 indicates a warning.
•
A warning does not cause a state change.
•
Warnings do not need to be reset.
More Lenze-specific status bits (bit 8 ... 15)
Device status
Bit pattern in the CiA 402 status word (
Bit 15
Bit 14
Bit 13
Bit 12
Bit 11
Bit 10
Bit 9
Bit 8
Not active
Brake
released
Following
error is
active
Drive fol-
lows set-
point selec-
tion
Internal lim-
itation is
active
Target posi-
tion
reached
Control
word pro-
cessed suc-
cessfully
RPDOs deac-
tivated
Brake applied
X
0
X
X
X
X
X
X
Brake released
X
1
X
X
X
X
X
X
Active
0
X
X
X
X
X
X
X
not active
1
X
X
X
X
X
X
X
X = state is not relevant
Detailed information on the various device states can be found in the following sections.
Configuring the network
Device profile CiA 402
Device states
324
Содержание i950 Series
Страница 1: ...Inverters i950 servo inverters Commissioning EN ...
Страница 2: ......
Страница 312: ...15 Configure engineering port The given path leads you to the engineering port Configure engineering port 312 ...
Страница 397: ...19 Safety functions Supported safety functions for Basic Safety STO 4Safe Torque Off STO 398 Safety functions 397 ...
Страница 497: ......
Страница 498: ......
Страница 499: ......