IrSlaveSyncOutPos
IrMasterSyncOutDist
= 2 IrSlaveSyncOutDist
IrSlaveSyncOutDist
eSyncMode = Ramp_Dist
xSyncPos
xAccDecSync
xSynchronised
Master-Position [u]
Slave-Position [u]
Fig. 52: Disengage clutch with clutching mode = 5
Relevant parameters of other functions
Address
Designation
Default setting
Setting range
Declutch position
0.0000
0.0000 ... 214748.3647
Deceleration of "direct declutching"
10000.0000
0.0000 ... 214748.3647
Clutch-in distance
90.0000
0.0000 ... 214748.3647
Declutch distance
90.0000
0.0000 ... 214748.3647
Configuring the "Sync and Correction" TA
Position clutch
Path-controlled clutch