16.1.5.1
Switch on
This command serves to deactivate the switch on inhibit which is active after switch on or
after the reset (acknowledgement) of an error.
A changeover to the "
" device status takes place.
A
From all states
B
Power section inhibited (pulse inhibit)
C
Power section enabled
Bit pattern in the CiA 402 control word (
Bit 15 ... 8
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Reserved
(specific)
Reset fault
Operating mode-dependent
Operation
enabled
Activating
quick stop
Establish read-
iness for oper-
ation
Switch-on
X
0
X
X
X
0
1
1
1
X = state is not relevant
Configuring the network
Device profile CiA 402