Functional description
The start of the homing process does not cause the drive to execute a homing
process. The initialisation and motion control are both executed autonomously
by the drive.
Referenzieren
abgeschlossen
t
x
t
max
t
0
0x2880:001
Timeout
SHOM available
SHOM start
SHOM active
SHOM load
0x2880:001
t
t
t
t
t
0
0
0
0
0
1
1
1
1
1
Fig. 79: Timing of the SHOM function
The homing process is for example started via the IRS signal (source can be set in
The safely limited speed (SLS) is always activated.
Within a time period defined in
reference signal is
expected via the input X82/IRL (SHOM-Load). The reference signal defines the safe reference
point
(home position) in the absolute area.
When the reference point has been defined, homing is completed. A changeover to normal
operation will follow.
Safety functions
Safe homing (SHOM)
429