Address
Name / setting range / [default setting]
Info
0x10F3:001
History buffer : Max. number of messages
•
Read only
Maximum number of messages that can be stored in the history buffer
(from subindex 6).
0x10F3:002
History buffer : Latest message
•
Read only
Subindex of the latest message.
0x10F3:003
History buffer : Latest acknowledged message
0 ... [0] ... 255
Subindex of the latest message acknowledged by the EtherCAT master.
0x10F3:004
History buffer : New active message
•
Read only
TRUE if messages are available that have not been acknowledged yet by
the EtherCAT master.
0x10F3:005
History buffer : Control bits
0 ... [0] ... 65535
Settings for sending and saving of the messages.
16.2.6
Diagnostics
The content of this section is currently being processed.
16.2.6.1
LED status display
The content of this section is currently being processed.
LED status display
Notes on the EtherCAT connection status and the data transfer can be obtained via the LED
displays "RUN" and "L/A" at the RJ45 sockets.
16.2.6.2
Information on the network
The content of this section is currently being processed.
The following parameters show information on the network.
Parameter
Address
Name / setting range / [default setting]
Info
0x2020:001
EoE information: Virtual MAC address
•
Read only
Display of the virtual MAC address.
0x2020:002
EoE information: IP adress
•
Read only
Display of the IP address.
0x2020:003
EoE information: Subnet mask
•
Read only
Display of the subnet mask.
0x2020:004
EoE information: Standard gateway
•
Read only
Display of the standard gateway.
0x2020:005
EoE information: DNS server
•
Read only
Display of the DNS server.
0x2020:006
EoE information: DNS name
•
Read only
Display of the DNS name.
0x2020:007
EoE information: Received packages
0 ... [] ... 4294967295
Display of the packages received during the EoE transmission.
0x2020:008
EoE information: Transmitted packages
0 ... [] ... 4294967295
Display of the packages sent during the EoE transmission.
16.2.6.3
EtherCAT master diagnostics
Parameter
Address
Name / setting range / [default setting]
Info
0x5851:001
EtherCAT master diagnosis: EtherCAT master state
•
Read only
Display of the EtherCAT master state.
0 Unknown
1 Init
2 Pre-Operational
3 Bootstrap
4 Safe-Operational
8 Operational
Configuring the network
EtherCAT
Monitoring
343
Содержание i950 Series
Страница 1: ...Inverters i950 servo inverters Commissioning EN ...
Страница 2: ......
Страница 312: ...15 Configure engineering port The given path leads you to the engineering port Configure engineering port 312 ...
Страница 397: ...19 Safety functions Supported safety functions for Basic Safety STO 4Safe Torque Off STO 398 Safety functions 397 ...
Страница 497: ......
Страница 498: ......